Property Management Click and Take the 20 Question Maintenance Man HVAC Quiz Lex Vance November 30, 2022 Hit Start Below & Take the HVAC Quiz 716 Created on November 29, 2022 By Lex Vance Take the Maintenance Man HVAC Quiz Hit start and take the 20 question maintenance man HVAC quiz. 1 / 20 If a fire damper malfunctions and closes inside the plenum above the air handler, what will happen? The air handler will not turn on. The pressures will drop and cause the unit to freeze up. The condenser fan will only turn on. 2 / 20 How does a heat pump HVAC unit heat an apartment? A Fan Blows Over a Heat Exchanger It Reverses the Flow of the Refrigerant It Uses Hot Water From the Water Heater 3 / 20 On a 40/5 capacitor, the fan should have how many microfarads? 40 45 5 4 / 20 If the thermostat is blank with no power, you should: See if the float switch has water in it. Start adding refrigerant until the low pressure switch restores power. Install a new air handler. 5 / 20 What does S.E.E.R. stand for? Stored Energy Efficiency Ranking Seasonal Energy Efficiency Ratio Standard Engineered Energy Rating 6 / 20 If you see a TXV inside an air handler, what temperature readings on the gauges are used to correctly charge that AC unit? Wet and Dry Bulb Temperatures Superheat Temperature Sub-Cool Temperature 7 / 20 When you see this Model Number SSZ140241AM on a standard Goodman, what tonnage is the unit? 2.5 ton 2 ton 3 ton 8 / 20 What does a dirty clogged air filter cause? Low refrigerant pressures which causes ice on the unit. The contactor to stick causing unit to run constantly. High refrigerant pressures which freezes the unit. 9 / 20 On a heat pump HVAC unit, if the thermostat is set to cool but the suction line is hot, what could be stuck? The contactor The reversing valve The capacitor terminals 10 / 20 Are the low 24 volts on an AC contactor on the side terminals or the top and bottom terminals? The Side Terminals The Top and Bottom Terminals Both Side and Top and Bottom Terminals 11 / 20 If you see a piston inside an air handler, what temperature reading on the gauges should you use to correctly charge that AC unit with refrigerant? Sub-Cool PSI Superheat 12 / 20 If you pull the cover off of a live HVAC thermostat and touch your volt meter leads to the red and common wires, how many volts should you read? 240 24 120 13 / 20 On a new HVAC system, what wires are usually separated by the float switch? White and Red or Yellow and Red Red and Green or Blue and Blue Red and Red or Yellow and Yellow 14 / 20 What is the person called who installs capacitors still in the box and unmounted? The run cap bandit The Scalawag The poot sniffer 15 / 20 On a new heat pump HVAC unit, what 24 volt low voltage wires have to have power for it to cool correctly? Red, Green, Yellow and Blue Red, Green, Yellow and White Red, Green, Yellow and Orange 16 / 20 If the liquid line is 87 degrees and the saturation on your red head pressure gauge is at 105 degrees, what's the subcool? 18 degree subcool 87 degree subcool 105 degree subcool 17 / 20 What should the suction line going into the compressor be when in cooling mode? All liquid refrigerant All nitrogen All gas refrigerant 18 / 20 What tool measures wet and dry bulb temperatures to get a target superheat? Infrared temp sensor gun Temperature pipe clamp Psychrometer 19 / 20 What are the 3 terminals called on a standard compressor? Cool, Heat, and Auto Common, Herm, and Fan Start, Run, and Common 20 / 20 If your suction line is 54 degrees and the saturation temperature on your blue suction pressure gauge is at 40, what's your superheat? 14 degree superheat 54 degree superheat 28 degree superheat Your score isThe average score is 78% LinkedIn Facebook VKontakte 0% Restart quiz Click HERE for FREE online training videos for maintenance technicians who work in property management. ← Test Your Maintenance Knowledge With a Quiz for Maintenance Technicians FREE Online Apartment Maintenance Tech Assessment Test →